Skip to main content
You're viewing the free public version. Create a free account for full research and member tools. Join free
Research Abstract

Delayed restoration of atrial function after conversion of atrial flutter by pacing or electrical cardioversion.

Jordaens L, Missault L, Germonpré E, Callens B, Adang L, Vandenbogaerde J, Clement DL
The American journal of cardiology
Jan 1, 1993
Sources
2 min read
0:00 / 0:00
0:00 / 0:00

Sign in to access this feature

Create a free account or sign in to use AI summaries, listen to articles, download PDFs, and save to your library.

2 views
Share:

Abstract

It is often suggested but never proven that atrial function is not affected during atrial flutter, nor after its conversion to normal sinus rhythm. To evaluate this hypothesis, a prospective study was performed in 22 patients (age range 20 to 88 years) with atrial flutter. Diastolic transmitral flow was analyzed with echo-Doppler before and after conversion. After randomization, conversion was attempted with overdrive pacing or up to two 50 J shocks. If the initial method was unsuccessful, a 200 J shock was administered. All patients were converted to sinus rhythm with this protocol. Shortly after conversion (at 1 and 6 hours), atrial contribution to ventricular filling was absent in 4 of 22 patients. In the remaining 18 patients, atrial contribution to ventricular filling was small. Atrial contribution to transmitral flow improved from 20 to 27% within 24 hours (p < 0.01) and increased further to 38% at 6 weeks (p < 0.005). Peak velocity of late diastolic filling increased from 0.28 m/s after 1 hour to 0.39 m/s after 24 hours (p < 0.0001) and improved even further during later follow-up. In 1 patient, an effective atrial systole was not observed until the 14th day. Cardiac output did not change significantly during the study period. No differences were observed between the conversion modalities. In conclusion, atrial dysfunction is present immediately after conversion of atrial flutter to normal sinus rhythm. This dysfunction occurs also after overdrive pacing and can last > 1 week. The findings suggest that stasis in the atria can remain temporarily present after successful conversion of atrial flutter to sinus rhythm.

Affiliation

Department of Cardiology, University Hospital Ghent, Belgium.

Comments

Sign in or create a free account to join the conversation.

Sign in to comment

Be the first to comment.

Trusted By Professionals and Teams:

The National Health Federation
Stand For Health Freedom
Global Healing Institute
Global Wellness Forum
MAHA Action
Myers Detox
Natural News
Mercola.com

Unlock Evidence-Based Health Research

Join 500,000+ members accessing 10,000+ natural health topics.

Subscribe to our informative Newsletter & Receive

Cancer Fighting Foods Ebook

Our newsletter serves 500,000 with essential news, research & healthy tips, daily.

Disclaimer: This article is not intended to provide medical advice, diagnosis or treatment. Views expressed here do not necessarily reflect those of GreenMedInfo or its staff.